{"product_id":"broadcom-megaraid-9670-24i-raid-controller-pci-express-x8-4-0-6-gbit-s","title":"Broadcom MegaRAID 9670-24i RAID controller PCI Express x8 4.0 6 Gbit\/s","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003ePCI Express 4.0 x8, 6Gb\/s, 3 x SAS SFF-8654 x8, RAID 0\/1\/5\/6\/10\/50\/60\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConnect up to 240 SAS\/SATA devices or 32 NVMe devices per controller\u003c\/li\u003e\n\u003cli\u003eSFF-8654 (SlimSAS) x8 connectors\u003c\/li\u003e\n\u003cli\u003eForm-factor friendly cable exit\u003c\/li\u003e\n\u003cli\u003eHardware Secure Boot and SPDM Attestation support\u003c\/li\u003e\n\u003cli\u003eSupport critical, high-bandwidth applications with PCIe 4.0 connectivity\u003c\/li\u003e\n\u003cli\u003eBalance protection and performance for critical applications with RAID 0, 1, 5, 6, 10, 50 and 60 and JBOD\u003c\/li\u003e\n\u003cli\u003eSFF-TA-1005 Universa Bay Management (UBM) Ready\u003c\/li\u003e\n\u003cli\u003eAdd more protection and peace of mind with CacheVault flash cache protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDescription\u003c\/h2\u003eThe MegaRAID 9600 series is the third generation of Tri-Mode x8 and x16 NVMe\/SAS\/SATA adapters. Designed to deliver the best possible performance for NVMe SSD-based storage systems, the 9600 family delivers 2x the bandwidth, over 4x the IOPs, 25x reduction in write latency and 60x increase in performance during rebuilds over the previous generation.\u003cbr\u003e\u003cbr\u003eThe MegaRAID 9670-24i adapter, based on the SAS4124 RAID-on-Chip (RoC), integrates a 2x72-bit high-speed DDR memory interface delivering faster speeds at 3,200 MT\/s and more than 4x increase in RAID5 Random Write IOPs over previous generation adapters. Gain the most flexibility out of your storage controller by direct connecting up to 24 Gen 4.0 NVMe, 24G SAS or SATA devices.\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported storage drive interfaces\u003c\/td\u003e\n\u003ctd\u003eSAS, Serial ATA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal SAS ports\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost interface\u003c\/td\u003e\n\u003ctd\u003ePCI Express x8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCI Express slots version\u003c\/td\u003e\n\u003ctd\u003e4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePerformance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAID levels\u003c\/td\u003e\n\u003ctd\u003e0, 1, 5, 6, 10, 50, 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS.M.A.R.T. support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of devices supported\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean time between failures (MTBF)\u003c\/td\u003e\n\u003ctd\u003e3000000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eMD2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData transfer rate\u003c\/td\u003e\n\u003ctd\u003e6 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels quantity\u003c\/td\u003e\n\u003ctd\u003e24 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eAustralia\/New Zealand RCM (AS\/NZS CISPR 32; CISPR 32:2015, Class A; AS\/NZS CISPR 32:2015, Class A), Canada EMC (ICES-003:2016 Issue 6: 2016, Class A; CAN\/CSA CISPR 22-10; CISPR 22:2008), Europe (CE) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020), Korea (KN32\/KN35), Taiwan BSMI (CNS 13438; CNS15663), USA\/Canada Safety (UL Listed) (UL 62368-1, Second Edition; CAN\/CSA C22.2 No. 62368-1-14), USA\/Canada (FCC) (47 CFR FCC Part 15, Subpart B, Class A; ANSI C63.4:2014; CISPR 32:2008) CB (IEC 62368-1:2014 (Second edition); EN 62368-1:2014+A11: 2017), Japan (V-3\/2015.04, Class A; V-4\/2012.04; VCCI-CISPR 32:2016; CISPR 32:2015), Morocco (CMIM) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eData transmission\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData transfer rate\u003c\/td\u003e\n\u003ctd\u003e6 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eTechnical details\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAID levels\u003c\/td\u003e\n\u003ctd\u003e0, 1, 5, 6, 10, 50, 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS.M.A.R.T. support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of devices supported\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eMD2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels quantity\u003c\/td\u003e\n\u003ctd\u003e24 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance certificates\u003c\/td\u003e\n\u003ctd\u003eRoHS, WEEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eMD2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eEndurance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean time between failures (MTBF)\u003c\/td\u003e\n\u003ctd\u003e3000000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption (typical)\u003c\/td\u003e\n\u003ctd\u003e24 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eCertificates\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eAustralia\/New Zealand RCM (AS\/NZS CISPR 32; CISPR 32:2015, Class A; AS\/NZS CISPR 32:2015, Class A), Canada EMC (ICES-003:2016 Issue 6: 2016, Class A; CAN\/CSA CISPR 22-10; CISPR 22:2008), Europe (CE) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020), Korea (KN32\/KN35), Taiwan BSMI (CNS 13438; CNS15663), USA\/Canada Safety (UL Listed) (UL 62368-1, Second Edition; CAN\/CSA C22.2 No. 62368-1-14), USA\/Canada (FCC) (47 CFR FCC Part 15, Subpart B, Class A; ANSI C63.4:2014; CISPR 32:2008) CB (IEC 62368-1:2014 (Second edition); EN 62368-1:2014+A11: 2017), Japan (V-3\/2015.04, Class A; V-4\/2012.04; VCCI-CISPR 32:2016; CISPR 32:2015), Morocco (CMIM) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eSystem requirements\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eServer operating systems supported\u003c\/td\u003e\n\u003ctd\u003eSUSE Linux Enterprise Server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWindows operating systems supported\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinux operating systems supported\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther operating systems supported\u003c\/td\u003e\n\u003ctd\u003eVMware vSphere ESXi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e155.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e111.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOther features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther operating systems supported\u003c\/td\u003e\n\u003ctd\u003eVMware vSphere ESXi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Broadcom","offers":[{"title":"Default Title","offer_id":53048401330523,"sku":"05-50123-00","price":1807.03,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0894\/4120\/6619\/files\/03GGEIpKv0Ke4xw5-VWr5w.c-m.jpg?v=1779427071","url":"https:\/\/strixly.co.uk\/products\/broadcom-megaraid-9670-24i-raid-controller-pci-express-x8-4-0-6-gbit-s","provider":"STRIXLY - DESKTOP PCs, GAMING PCs, LAPTOPS \u0026 MORE","version":"1.0","type":"link"}